Target quantity before geometric detail
Heat duty, pressure demand, distribution or particle paths can govern a plant decision. Required detail follows from the local effects that influence those targets.
From detail to an equivalent model
First characterise a heat exchanger through sizing calculations or a detailed model. An equivalent resistance and suitable heat-exchange representation transfer its behaviour into the complete system.
Compare benefit and effort
An added insert or changed tube geometry can provide little benefit while complicating manufacturing or cleaning. The comparison places the computed effect in the context of those design requirements.