Project study

Fan characteristic in an installed configuration

A CFD-to-measurement study considered an axial fan within its test or installation geometry and extended the comparison across geometric variants.

Geometry comparison of three installed axial-fan configurations
Process & plant engineering · CFD simulationGeometry comparison of installation variants
Industry
Process & plant engineering
Services
CFD simulation

Engineering question

The free-fan characteristic had to be distinguished from the effects of the surrounding nozzle, opening and connection geometry.

Model & approach

  • Model the measurement arrangement and installed fan as one flow domain
  • Compare characteristic points and geometry variants with a consistent evaluation method

Boundary conditions

  • Steady fan operating points in the installation assessed
  • Measured fan characteristic as the comparison basis

Results of the assessment

  • Calculated characteristic points were compared with the measured fan characteristic.
  • The variant study extended the characteristic comparison to the effect of installation geometry.

Engineering consequence

The study supported assessment of the nozzle, opening and connection geometry in the installed fan system.

A similar question?

Let’s clarify the objective, available data and useful model fidelity.

Discuss a similar question